INSTRUCTIONS OF USE FOR
Safe Plus
EDMA GROUP, LLC
3634 PICCADILLY RD,
PHEONIX, AZ 85018
INSTRUCTIONS OF USE FOR
SAFE PLUS
EDMA GROUP, LLC
3634 PICCADILLY RD,
PHEONIX, AZ 85018
EN 420:2003+A1:2009 / EN ISO 21420:2020
WARNING: SINGLE USE GLOVE
This product has been manufactured following the requirements of Regulation (EU) 2016/425, for its basic use, according to the standard EN 420:2003+A1:2009 / EN ISO 21420:2020 (Protective gloves — General requirements), EN ISO 374-1:2016/A1:2018 (Protective gloves against dangerous chemicals and micro-organisms – Part 1: Terminology and performance requirements for chemical risks) and EN ISO 374-5:2016 (Protective gloves against dangerous chemicals and micro-organisms – Part 5: Terminology and performance requirements for micro-organisms risks), as stated in the certificate No. UE-000035/00 issued by Eurofins Textile Testing, C/ Germán Bernácer nº 4, 03203 Elche-Alicante, Spain, Notified Body No. 2865.
This PPE is made of the following materials: Powder-free blue Nitrile.
THE MANUFACTURER DISCLAIMS ALL RESPONSIBILITY FOR DAMAGES OR DETERIORATIONS CAUSED BY UNAUTHORIZED MODIFICATIONS MADE TO THE PPE BY THE USER.
- Dirt or substance residues adhering to the glove can impair its performance.
- Protective equipment does not act as a chemical barrier at the molecular level.
- The glove has to be removed carefully to avoid any product residue left on the surface of the PPE from coming into contact with the skin.
- Carry out an inspection before putting on the PPE to ensure that it is in perfect condition.
- This product does not offer protection against gases and vapors.
- The user must know the use and handling of the glove.
- This product must not be used against risks other than those described above.
- EN 374 -4:2013 Degradation levels indicate the change in puncture resistance of the gloves after exposure to the challenge chemical.
- “This information does not reflect the actual duration of protection in the workplace and the differentiation between mixtures and pure chemicals.”
- “The chemical resistance has been assessed under laboratory conditions from samples taken from the palm only and relates only to the chemical tested. It can be different if the chemical is used in a mixture.”
- “It is recommended to check that the gloves are suitable for the intended use because the conditions at the workplace may differ from the type test depending on temperature, abrasion and degradation.”
- “When used, protective gloves may provide less resistance to the dangerous chemical due to changes in physical properties. Movements, snagging, rubbing, degradation caused by the chemical contact etc. may reduce the actual use time significantly. For corrosive chemicals, degradation can be the most important factor to consider in selection of chemical resistant gloves·”
- “Before usage, inspect the gloves for any defect or imperfections.”
Penetration | ||||
---|---|---|---|---|
EN 374-2:2014 | Air Leak / Water Leak | PASS |
Permeation performance level | ||
---|---|---|
Measured breakthrough time | Permeation performance level | |
> 10min. | Level 1 | |
> 30min. | Level 2 | |
> 60min. | Level 3 | |
> 120min. | Level 4 | |
> 240min. | Level 5 | |
> 480min. | Level 6 |
PROTECTION AGAINST VIRUS EN ISO 374-5:2016 | ||
---|---|---|
ISO 16604, Procedure B | PASS |
CHEMICALS EN ISO 374-1:2016/A1:2018 | ||
---|---|---|
Code | Chemical | CAS number |
K | Sodium hydroxide 40% | 1310-73-2 |
P | Hydrogen Peroxide 30% | 7722-84-1 |
T | Formaldehyde 37% | 50-00-0 |
Chemical | Level | |
EN 16523:2015 Permeation | Sodium hydroxide 40% (K) | 6 |
Type B | Hydrogen Peroxide 30% (P) | 4 |
KPT | Formaldehyde 37% (T) | 4 |
Chemical | Mean Degradation % | |
EN ISO 374-4:2 013 Degradation |
Sodium hydroxide 40% (K) | -7.4% |
Hydrogen Peroxide 30% (P) | 25% | |
Formaldehyde 37% (T) | 41% |
Size | Hand circumference (mm) | Glove length (mm) |
---|---|---|
6 | 152 | 220 |
7 | 178 | 230 |
8 | 203 | 240 |
9 | 229 | 250 |
10 | 254 | 260 |
11 | 279 | 270 |
Store the glove avoiding unnecessary sun exposure and in dry places, protected from any aggressive agent.
The gloves will be packed in boxes.
Keep out of sun
Keep dry
Temperature limited
(5ºC-35ºC)
Do not use if packaging is damaged
Store the glove avoiding unnecessary sun exposure and in dry places, protected from any aggressive agent.
The gloves will be packed in boxes.
The glove has a useful life of
3 years
Year of manufacture:
11 / 2020
Batch Code
E1E48021D01AH
Latex free
Non sterile